KP8011 5 va/vb plastic vertical burning test machine (500 w flame tester)
1. Scope of application:
Suitable for solid materials and performance equal to and greater than 250 kg/M3 density foam. Requires the use of two different shape test samples in characterization of the properties of rectangular bar of the test sample to evaluate the flammability and combustion time of material, rectangular test sample to evaluate the ability of resistance to burn through the material.
2. Standard:
Conform to GB/T5169.17-2008 "500 w flame test methods", IEC60695-11-20 of UL94 5 va and vb, ASTM D 5048, ISO10351 test standard.
3. The combustion housing:
Enclosure: 0.75 m3, adopt CNC machine processing molding, circular modelling beautiful generous. High-quality SUS304 stainless material/painting, has the characteristics of beautiful and rust corrosion.
Breeze for the box body at the top of the exhaust system, the test is completed, will waste gas exhaust to the outside; During the trial, this system is to stop state.
Enclosure front in the process of the test can be sealed toughened glass observation window, convenient for observation test.
Illuminometer: the casing of the intensity of illumination < 20 lx
4. The combustion burner:
This burner, made by the company completely in line with GB/T5169.15-2008 flame A or C.
Specification: of the crater Ф 9.5 mm inner diameter, injection steam eye: Ф 0.9 + / - 0.03 mm, the height between nozzles and air inlet for 100 + 10 mm
Torch Angle: the Angle to the vertical axis is 20 degrees;
Flame height: for 38 mm inner flame, the flame height 135 mm.
5. The temperature measuring system:
Thermoelectric decoupling: 0.5 mm armoured thermocouple; Can be measured temperature 1050 ℃
Copper: diameter is 9.0 mm, is 10 g in weight
Thermometer: intelligent PID temperature controller and match the K type thermocouple. Heat from 100 ℃ to 100 ℃, time of 54 s
Timer: accurate to 0.1 S
6. Other technical parameters:
Methane gas flow rate: 150 ~ 1500 ml/min is adjustable;
The air flow: 1 ~ 10 l/min
Pressure gauge, measurement range 0 ~ 7.5 kPa
Control valve, gas and air flow control in the specified range.
Gas source: purity of not less than 98% of the methane. () by advertisers
Air source: 4 kg of air compressor () by advertisers
Automatic timer, automatic ignition
Timer: 0 ~ 99.99 s can be arbitrary set, accuracy 0.1 s or less
Flame height gauge: inner flame 38 mm, 135 mm, outer flame for 0.5.0 mm error.