AC and DC High Proof tracking tester TrackingInspection Report
Test Standard |
Model |
Power |
Humidity |
Ambient temperature |
Weather |
GB6553、IEC60587 |
KP8047 |
6kw |
50% |
23℃ |
Sunny day |
Calibration Instruments |
Voltage tester QS-50、Stopwatch 、Multimeter、Electronic Balance |
||||
Parameter name |
No. |
Standard values |
actual value |
actual Deviation |
Standard Deviation |
AC Voltage |
1 |
0.5KV |
0.46KV |
-0.04KV |
±5% |
2 |
1KV |
1.07KV |
+0.07KV |
||
3 |
2KV |
1.98KV |
-0.02KV |
||
4 |
3KV |
3.26KV |
+0.26KV |
||
5 |
4KV |
4.14KV |
+0.14KV |
||
6 |
6KV |
6.23KV |
+0.23KV |
||
AC Voltage |
1 |
-0.5KV |
-0.48KV |
-0.02KV |
±5% |
2 |
-1KV |
-1.05KV |
+0.05KV |
||
3 |
-2KV |
-1.97KV |
-0.03KV |
||
4 |
-3KV |
-3.24KV |
+0.24KV |
||
5 |
-4KV |
-4.11KV |
+0.11KV |
||
6 |
-6KV |
-6.2KV |
+0.2KV |
||
Liquid Flow |
1 |
0.07ml/min |
0.071ml/min |
+ 0.001ml/min |
±0.6% |
2 |
0.15 ml/min |
0.152 ml/min |
+0.002 ml/min |
||
3 |
0.30 ml/min |
0.297 ml/min |
- 0.003ml/min |
||
4 |
0.60 ml/min |
0.596 ml/min |
- 0.004ml/min |
||
5 |
1.0 ml/min |
1.003ml/min |
+0.003 ml/min |