KePin (DongGuan) Testing Instruments Co., Ltd.
0086-769-88034181E-mail:server@kepin17.com  Homepage-Favorite   Language:中文 English
  • Home
  • About
  • Instrument
  • Download
  • Case
  • Job
  • Contact Us
  • Affiliate
  • Search
Tracking index tester--Needle flame tester--Glow Wire Tester--UL94 Vertical Horizontal burning tester--Dielectric breakdown voltage Testers

Instrument

Building Materials
Wire and Cable
fire retardant paint
Electronics
Building part
Plastics, polymers

Contact Us

 KEPIN fire testing technology ltd
 Global service hotline:
 0086-769-88034181
 Email:server@kepin17.com
 CN website:
 http://www.kepin17.com
 EN website:
 http://www.kepin17.com/en/
 Address:Changan Xin'an community hengzheng Road shongbo Business Centre No.102 Dongguan city

Current Location:Home > Instrument > Wire and Cable
Wire and Cable

KP8026A single wire cable vertical burning test machine (with no fume hood)

KP8026A single wire cable vertical burning test machine (with no fume hood)
  • modelKP8026A
  • standardGB/T18380.11-2008、GB/T18380.12-2008、GB/T18380.13-2008、IEC60332-1-1:2004、 IEC60332-1-2:2004 、IEC60332-1-3:2004、GB/T18380.21-2008、GB/T18380.22-2008、 IEC60332-2-1:2004、IEC60332-2-2:2004

Detailed description

KP8026A single wire cable vertical burning test machine (with no fume hood)
 
1, scope of application:
Applies to provisions of fire under the condition of single cable or optical cable fire vertical slow delay test
Second, conform to the standard;
In line with the GB/T18380.11-2008, GB/T18380.12-2008, GB/T18380.13-2008, IEC60332-1-1 - "04 04, IEC60332-1, IEC60332-1-04
Conform to GB/T18380.21-2008, GB /, IEC60332 T18380.22-2008-2-1:4, IEC60332-2 - "04
 
One, the main parameters:
 
1, the metal cover: height of 1200 mm, 300 mm wide, 450 mm deep, open the front and the top and bottom seal.
 
2, the torch:
 
2.1, GB/T18380.11-2008, GB/T18380.12-2008, GB/T18380.13-2008, IEC60332-1-1 - "04 04, IEC60332-1, 1-04 his IEC60332 - USES the nominal power is 1 kw of the burner. Accord with standard of GB/T5169-14.
2.2, GB/T18380.21-2008, GB /, IEC60332 T18380.22-2008-2-1:4, IEC60332-2 - "4 USES the propane burner type (diffusion flame).
 
3, set the burning time reaches the preset time, the machine will automatically stop the ignition.
4, automatic ignition for high-voltage fire.
5, fuel, gas, methane () by advertisers
6, air flow meter: 10 l/min, a gas flow meter 650 ml/min
7, a temperature measuring device
 

Clicks:  Updated:2013-06-15 15:28:42  【Print this page】  【Close】
Previous:KP8026B single wire cable vertical burning test machine (fume hood)  Next:KP8024 Get wet in the rain cable impact vibration/combustion testing machine
Quick NavigationAbout KEPINTechnical Support
InstrumentCompany ProfileService
Standard DownloadContact UsPartner
Manual DownloadInformationAffiliate
MessageVideo CenterSiteMap
Search
0086-769-88034181

KePin (DongGuan) Testing Instruments Co., Ltd. All rights reserved

Address: the second industrial zone ssangyong's night side, dongguan city road too coupon lane no. 1 industrial park
Technical support: 13729993710 Mr Wang email:server@kepin17.com

KePin Detection technologyTo provide you with professionalTest equipment、Flame retardant test equipment、The cable tester、High polymer material tester
科品仪器-建筑材料燃烧试验机-燃烧性能分析测试仪-材料阻燃等级试验