KePin (DongGuan) Testing Instruments Co., Ltd.
0086-769-88034181E-mail:server@kepin17.com  Homepage-Favorite   Language:中文 English
  • Home
  • About
  • Instrument
  • Download
  • Case
  • Job
  • Contact Us
  • Affiliate
  • Search
Tracking index tester--Needle flame tester--Glow Wire Tester--UL94 Vertical Horizontal burning tester--Dielectric breakdown voltage Testers

Download

Manual Download
Standard Download
Other Download
Sample inspection report

Contact Us

 KEPIN fire testing technology ltd
 Global service hotline:
 0086-769-88034181
 Email:server@kepin17.com
 CN website:
 http://www.kepin17.com
 EN website:
 http://www.kepin17.com/en/
 Address:Changan Xin'an community hengzheng Road shongbo Business Centre No.102 Dongguan city

Current Location:Home > Download > Standard Download
Standard Download

ISO 19700-1 to control the fire airflow measurement equivalence ratio method of toxic components

  • Updated2013-07-01 18:26:14
  • File Download Click to download

Detailed description

ISO 19700-1 to control the fire airflow measurement equivalence ratio method of toxic components

This standard describes the used for fire gas generated and determination of composition of combustion products and determine a method of pipe type furnace, especially in an fire generated within the framework of the toxic products of decomposition conditions. It USES - mobile specimen and tube furnace at different temperature and gas flow as the fire simulation.

This method has been designed for use as a - TC92 level B group of performance-based engineering method, hazard assessment and fire safety engineering calculation provide input data. In different temperature, flameless and flaming decomposition conditions and different in the tube furnace fuel/oxygen ratio are combined, the method can be widely used to simulate fire conditions. These include as ISOXXX table XX fire described in the following types:

- phase 1: no flame

- phase 1 b) oxidative pyrolysis from external radiation;

- phase 2: well ventilated with flame (on behalf of - is there a fire flame development) 1;

- phase 3: good ventilation with flame 2:

- phase 3 a) in a closed small or poor ventilation partition destructive fire;

- phase 3 b) in large or open fire after the flashover in the partition.

Among them 1: compared with the size of the partition size, fire flame below the hot gas layer base level and size of the fire is controlled fuel.

2: compared with the size of the partition size may be large, fire flame is higher than the heat and fire size at the bottom of the layer is controlled

Clicks:  Updated:2013-07-01 18:26:14  【Print this page】  【Close】
Previous:Rut tester operation panel   Next:The national electrical and electronic products environmental conditions and environmental tests GB standard equivalent IEC standard table
Quick NavigationAbout KEPINTechnical Support
InstrumentCompany ProfileService
Standard DownloadContact UsPartner
Manual DownloadInformationAffiliate
MessageVideo CenterSiteMap
Search
0086-769-88034181

KePin (DongGuan) Testing Instruments Co., Ltd. All rights reserved

Address: the second industrial zone ssangyong's night side, dongguan city road too coupon lane no. 1 industrial park
Technical support: 13729993710 Mr Wang email:server@kepin17.com

KePin Detection technologyTo provide you with professionalTest equipment、Flame retardant test equipment、The cable tester、High polymer material tester
科品仪器-建筑材料燃烧试验机-燃烧性能分析测试仪-材料阻燃等级试验