Xinan silicone order by high voltage tester order no. 20120706003
Communication: 6 kv
Dc: 8 kv
Mark since high voltage tester
Special note: instrument shell adopts 304 stainless steel material, liquid injection device and a set of protection device inside the case; Five groups of specimens require a separate control;
Including air compressor a, electromagnetic valve spare parts 5, liquid injection vulnerability spare part five, the fuse giving five.
scope of application:
Suitable for electrical and electronic products, household electrical appliances and materials of electric mark and erosion test, simulation in power frequency (48 hz - 62 hz), with liquid pollutants and cant specimen, by measuring electric mark and erosion resistant evaluation under harsh environmental conditions using the electrical insulation of electric resistance and erosion grade.
conforms to the standard:
GB/and IEC60587 T6553-2003-2003.
main parameters:
1. Voltage: AV: 0 ~ 6 kv plus or minus 5%, adjustable DC: 0 ~ 8 kv adjustable when test in the high pressure loop current reach or exceed 60 ma lasts 2 s after the relay operation, cut off the current, the buzzer alarm indication product is unqualified, then cancel the alarm according to the voltage can be stopped.
2. The filter size: making according to requirements of the standard size, the thickness of the filter paper is 0.15 ~ 0.17 mm.
3. The drip device: drip device height is adjustable, pollution liquid flow rate in 0.075 ~ 0.9 mL/min is adjustable, the test time can be preset.
4. The drip time interval: 0 ~ 99.99 S continuous adjustable.
5. Pollution liquid: ammonium chloride, isooctyl phenoxy poly ethoxy ethanol, nonionic wetting agents with distilled water or deionized water mixture. Liquid pollution in (23) 1 ℃ resistivity should be Ω • m (3.95 and 0.05).
6. The electrode: upper and lower electrode thickness of 0.5 mm, is 304 stainless material, size, in accordance with requirements of the standard size
7. Making, upper and lower electrode spacing between 50 + / - 0.5 mm.
8. The power supply requirements: AC220 (+ / - 10%) V / 50 hz.
equipment structure:
1. The instrument appearance size: 1200 * 1050 * 610 w h l (mm).
2. The work box size: 950 * 900 * 600 w l h (mm); Volume of 0.5 cubic meters.
3. The instrument for the overall structure, the control panel is located in the right side of the test chamber.
4. The working area is equipped with the door of glass Windows, in order to observe the test in the process of test process.
5. Is capped with a fan, when the test is completed, open the exhaust system, the waste gas emitted. (the system need to exhaust pipe, need) by advertisers
components, material:
1. The case material: high quality (t = 1.2 mm) electrostatic steel plate, with the numerical control machine tool processing molding, arc surface, pensu processing, more bright and clean and beautiful. (fee can do stainless steel chassis,)
2. All of the electrode, tightening device and are connected to the electrode assembly parts, such as screws, washers, nuts and mechanical parts made, 304 stainless steel against corrosion.
control system:
1. The relay control system, all have electronic originals adopt domestic leading brand, can better guarantee the performance of the machine and testing accuracy.
2. The equipment has the following safety protection device: power overload, short circuit protection, overload protection of control circuit.
environmental conditions of use:
1. There is no strong electromagnetic radiation source nearby.
2. The maintenance of equipment around with adequate space.
(3) temperature: 23 + 2 ℃.
4. Air pressure: 86 ~ 106 kpa.
5. AC220V / 50 hz.
6. Allowed range: voltage 220 v + / - 10%.
7. Allowed range: frequency 50 hz plus or minus 1%.
8. Require the user to the installation site for equipment configuration corresponding capacity of power switch, the switch must be independent and dedicated for the use of this equipment.
9. When the device does not work, the temperature of the environment shall be maintained within + 0 ~ 45 ℃.