Hubei electric power cable jacket a scratch-resistant grinding machine order - order no. 20120515001
Please note: the customer biggest wire is 170 mm
KP8114 cable jacket scratch-resistant grinding machine production of technical indicators:
1. The scope of application:
L suitable for wire and cable diameter (30 ~ 110) mm plastic blow grind resistance of coat.
2. Standard:
L, GB/T2951.28-2008 standard requirement.
3. The main parameters:
L blade radius: r1.5 mm
L a head trip: > 600 mm
L blow grind speed: 200 mm/s (100 + / - 50 mm)
L/t: 65, 106, 155, 106, 270, 340, 420, 500 n, 550 n
L sample length: 1 m
L power requirement: AC220 (+ / - 10%) V / 50 hz.
L experiment box running power: 2.5 KW.
4. Equipment structure:
L chassis frame for whole structure form, the work surface located in the central part of the whole machine, directly above the machine's control panel.
L sample clamp piece about a piece of each, compress the handwheel located at the top of the chassis, the installation of more convenient sample.
5. The component, material:
L case material is made of high quality (t = 1.2 mm) electrostatic steel plate, surface coating processing, more bright and clean and beautiful.
L mechanical parts with iron materials, thickening plating surface. Surface rust and beautiful.
6. Mechanical drive system:
L mechanical movement by AC dc motor + sprocket chain connection structure.
7. Control system:
L host USES the relay control system, have all electronic parts adopt domestic leading brand, can better guarantee the performance of the machine and testing accuracy.
L equipment has the following safety protection device: power overload, short circuit protection, overload protection of control circuit.
8. The environmental conditions of use:
L the machine to use industrial oxygen, or compressed air, the customer should bring along their own.
L near no strong electromagnetic radiation source.
L leave proper maintenance space around the equipment.
L temperature: room temperature ~ 40 ℃.
L pressure: 86 ~ 106 kpa.
L AC220V / 50 hz.
L voltage allowed range: 220 v + / - 10%.
Allow range: l frequency 50 hz plus or minus 1%.
L require the user to the installation site for equipment configuration corresponding capacity of power switch, the switch must be independent and dedicated for the use of this equipment.
L device does not work, the temperature of the environment shall be maintained within + 0 ~ 45 ℃.